Showing posts with label frayed cable. Show all posts
Showing posts with label frayed cable. Show all posts

Wednesday, December 22, 2010

Hemp House Rigging - The 'old fashioned way'

Dawn Wilfong, 24, works the fly rail and hauls a piece of coiled rope during a performance of “A Christmas Carol.”  (c) 2010 Photo by Thomas Slusser (For The Virginian-Pilot)

Check out this great story about one of the few remaining active rope rigging houses.  http://hamptonroads.com/2010/12/behind-scenes-wells-theatre-rare-find

This wooden pin-rail is in a theatre built in Texas in the 1920's.

One of the most common scenarios this blogger sees is equipment like this that has never been serviced in 50-70+ years.  The Loft Blocks are sometimes made of dry-rotted wood or sand-cast pigiron, either of which could fail under load without notice.  The ropes need constant review and regular replacement, too, as they weaken with age and abrasion.  As you can see in the second picture, the facility operators in this building don't understand the concept of counterweighting the batten loads, so everything is stage-heavy.  The battens are dead-hauled (bull-dogged) up, and if the tie-off fails or the fly crew looses their grip, then the batten and load will will come crashing to the stage.

Other potential problems are retro-fitted belaying pins:   I've found rebar, conduit, gas pipe, broom handles, steel spikes, and other odd items used in place of the correct items.  Some hemp-house facilities are 'hand-me-down' theatres that started-out as the High School Auditorium, then was the Middle School, and is now part of the Elementary School facility.  Not only is the equipment MORE DANGEROUS, but it is located where young children not familiar with the hazard potential can pull-out the belaying pins and/or untie the rope lines.

It is extremely important that the operators and staff fully understand how the fly system works and what safety precautions must be taken when loading and operating the system.

Thursday, April 30, 2009

Electrical Safety - Grounding continuity

When you think that your lighting batten is inherently grounded, you may want to check that it really is grounded. Modern rigging systems use Nylatron (plastic) pulleys and the counterweight carraige arbor shoes may be Nylon, leaving the only electrical path back to the safety ground as the ground wire in the SO power cable or flexible conduit that feeds your plugstrip or plugbox. If the fixed conduit or flex conduit body is the only ground path you have, then the ground is broked (open circuit) if the conduit becomes separated.

The same is true if your ground lead on a lighting instrument becomes disconnected. This can happen several ways:
  • A two wire connector (an old style two-pin 2P&G stage plug or a two-bladed Edison plug) is installed on a three-wire cable
  • A ground-lift adapter is installed on the end of a normally grounded NEMA 5-15P connector
  • The wire breaks internally
  • The wire gets yanked-out of the connector body
  • The wire gets yanked out of the lighting instrument body

In any case, you are in a situation that would let the fault current of an internal problem in a lighting instrument look for another path back to the source, and that path may be you!

Wednesday, April 29, 2009

Electrical Safety - Equipment Maintenance

Most stage equipment that uses electricity has a power cord with a (male) plug or (female) receptacle on one or both ends of it. Maintaining those connections is vital to both the operation of the device and the safety of those using it. Below is the back-end of a stage lighting instrument that has the cable strain relief missing, which in-turn allowed the inner wiring to become frayed and short-out to the casing. Here is a cable end plug that was hurredly assembled to get it working for a show, but the cable clamp (strain relief) was never tightened-down to take the stress off of the inner conductors.
Here is a 2P&G cable end that was not properly secured to the outher sheathing of the stage lighting instrument cable, and over time it frayed apart.
The same thing can happen to extension cords, twofers, and just about any other cable connection. When you find these types of equipment damage, the best thing to do is red-tag the equipment as non-usable, and submit it to your repair shop for correction

An ounce of prevention
In general, the root cause of these types of connector failures is due to people yanking on the cable instead of grasping the plug body when they remove them from their mating device. Take care of your equipment and it may not seek revenge by failing at five minutes to eight, or worse yet, shocking you to get your attention.