Wednesday, March 13, 2013

"Oh, that couldn't possibly happen here . . ."

Famous last words.  Not words to live by, either.  The bloggers at Cue To Cue on the BackstageJobs web site have posted a great summary about many of the Theatre and Assembly Space Fires that scorched millions of dollars worth of facilities last year.  Go here to read about them:

Theatre fires are not “something that used to happen.” There were at least 14 just this year.

Of particular interest are the video clips of the scenery and drapery fires that occurs on-stage during a performance.  Luckily, they didn't result in the 600+ deaths that the Iroquois Theatre fire caused, but the circumstances were largely the same - and this blogger sees the set-up for this type of fire ALL THE TIME!  Fireproof your sets - its not just a good idea - its the law! Ref:  NFPA 101 Life Safety Code - Chapter 13, Section 13.4.5.11

For schools and other theatre owners that don't have, or are planning to omit fire curtains from your venue, take a serious look at your fire prevention and control planning - because this could happen in your building, too!

Tuesday, November 6, 2012

Welding Spark Causes Fire at Bronx Theater

Nov 5, 2012 - Bronx, New York.  FDNY rolled multiple fire-fighting units on Monday in response to smoke and fire at the historic landmark Paradise Theater.  The fire resulted from welding sparks that entered an air duct as work was being done to restore the 1929 venue.  Fire crews remained on the scene for several hours to ensure that the fire did not restart due to overlooked pockets that might be hidden in walls or other building voids.  Most of the damage to the building is thought to be smoke related, with some water damage.

Bronx Paradise Theater - Photo Credit: Niko J. Kallianiotis for The New York Times

The 4000 seat Paradise Theater is one of the last Atmospheric theaters that employed a dark blue ceiling to create the effect of an open night sky above the audience.  Originally designed and used for both Vaudeville shows and cinema, the interior of both the lobby and the audience chamber is ornate.  The elaborate wall murals that portray Italian Baroque buildings extend across the painted fire curtain.  More history of the building can be found at: http://cinematreasures.org/theaters/900.

The auditorium is the second largest in New York, only smaller than Radio City Music Hall, and the 23rd largest auditorium ever built in the country.  It was designed by John Eberson, who was one of the most prominent theater designers in the United States and inventor of the Atmospheric style, the theater sought to transport visitors to an outdoor Baroque Italian garden of marble pillars, cypress trees, plaster replications of Michelangelo sculptures, vines, stuffed birds, and even a goldfish pond.  With a painted ceiling of stars bearing the constellation of Marcus Loews' birth sign and a smoke machine producing simulated clouds, viewers felt they were sitting under an evening sky. The result was a multi-sensory movie experience, an escape.  According to Eberson, the auditorium was "a magnificent amphitheatre under a glorious moonlit sky where friendly stars twinkled and wisps of cloud drifted."  Additional descriptions of the theater can be found at: www.placematters.net/node/1310 and:  http://en.wikipedia.org/wiki/Paradise_Theater_%28Bronx,_New_York%29


Friday, July 13, 2012

Keeping it all together

GRC (Not the Nutrition Guys) is a term commonly used to abbreviate Governance, Risk Management, and Compliance in the safety industry.  It is supposed to be an organizational cohesion that coordinates the efforts of everyone in a business so that guidance (Governance) is uniformly applied to all the sub-groups, and the subgroups share information and resources openly.

School Districts and Universities typically show significant separations between Risk Management (aka insurance claims management), Facility Safety (building and equipment maintenance), Public Safety (security), and personnel safety (actually training staff and students).

Interdepartmental separations occur, too.  Why is it the automotive shop student is given protective eye wear, while the theatre shop student has to provide his own?  The disparities are numerous and sometimes frustrating.  It affects the supply of safety information, safety goods, safety training, and maintenance.  When properly implemented, it answers the question of "Who's going to pay for this?"

For the governing administrators to do their jobs effectively, it is critical that they understand the wide variety of environments under their care.  In the theatre, this means that we have to pull-back the curtain and expose ourselves to the scrutiny of other non-theatre people.  This is hard.  We spend our entire careers trying to create magic and not let anyone outside of the theatre process know how it really works.  This is the exception.  When it comes to safety - everyone has to know and understand.

Don't stand there and tell everybody that your theatre is safe.  It's not.  This blogger sees brand new theatres that are constructed unsafely all of the time, and few new facilities come with any significant amount of operational safety training - everybody just brings their old bad habits with them and go on with little or no thought as to how they might make cultural changes to their work process.

In the 70's, the phone company ran a series of advertisements that said: "To communicate is the beginning of understanding."  The theatre plant is a perfect example of how important this is.  Maintenance workers need to access equipment and understand what is 'special' theatre equipment and know when they can work on it, and what is 'off limits' so that only specially qualified personnel are brought in to service it.  Good examples might be:
  • Dimmer Racks:  The air filters need to be cleaned regularly.  This may require that the power to the dimmer rack be disconnected because there may be live electrical parts within.  Chasing-off the cleaning crew and then not having the filters serviced may cause the dimmers to overheat and malfunction, or even catch fire.  At a minimum, it will shorten the life of the equipment.  This applies to the air filters for the workspaces around the theatre, too.  I've seen clogged air filters and air grilles in follow spotlight rooms, on stages, in dimmer rooms, and on dimmer racks - all preventable if the theatre staff would engage with the maintenance staff.
  • Stage Rigging:  Equipment must be inspected regularly by qualified personnel.  Most janitors and building maintenance crews are NOT trained or experienced enough to perform this task.  The maintenance of the stage rigging falls into this category.  The oil field rigging, construction rigging, or ship rigging backgrounds that some maintenance workers might have may be of some use, but without a knowledge of theatrical systems and how they are used, the resulting 'fixes' may be dangerous, incompatible with the theatrical operational needs, or aesthetically undesirable.
  • Fire Curtain, Smoke Vent, and Fire Doors:  Inspections and maintenance present challenges similar to the Stage Rigging.  Corrections that are not compatible with Fire Codes, Theatre Operations, and the Audience's enjoyment of the presentations must be prevented through the use of knowledgeable people.  Hire a consultant of you need one - this is where your Risk Management Department and or your Safety Office may be able to assist in securing the necessary funding.
Finding a balance with safety equipment provision policies, cost deferrals, and training budgets can only be achieved if the various participants can speak openly about the needs of their buildings and operations.  It also requires that the administrators truly understand and acknowledge just how dangerous a theatre plant is.  They care about bad brakes on buses, broken playground equipment, football helmets, and toxic fumes in the chemistry lab - why should your performing arts venue be any different?

Blogger Norman Marks on the Sustainable Business Forum site has a series of articles that help to explain GRC:  http://sustainablebusinessforum.com/node/59561

Thursday, December 30, 2010

107th Anniversary of the Iroquois Theatre Fire

As we start the new year let's take a moment to look around our facilities with a fresh set of eye's.  It never ceases to amaze me at the number of obvious fire hazards I see when visiting theatres, gymatoriums, cafetoriums, and other assembly spaces.

It sometimes seems like we haven't learned anything since that fateful day in Chicago where over 600 people lost their lives.  These are the common fire code violations I frequently see that also fueled the Iroquois Theatre tragedy:
Learn not to burn.  Keep your Fire and Smoke Protective Systems working properly and accessible.

Here is a blog entry from Lori Green at Ingersol-Rand Security Technologies, the manufacturers of Von-Duprin Door hardware.  They make one of the few crash-bar exit systems that don't make a lot of noise - Great for Theatres!  http://idighardware.com/2010/12/iroquois-theater-fire/

Wednesday, July 21, 2010

2010 LDI Show Schedule Available - Sign-up NOW!

The LDI International trade show has grown over the years to include much more than just stage lighting. You will also find sound, rigging, staging, video, projection, special effects, and thousands of tools to do your job more efficiently and safely. This year's show in Las Vegas (aka: Lo$t Wage$) runs Monday, October 18 thru Sunday, October 24 at the Las Vegas Convention Center.

Of particular interest is the growth of show production safety workshops being presented by ETCP trainers:
  • Stage Rigging Fundamentals - two days (L27)
  • Ohm's Law and Order: Essential Electrical Training - two days (L28)
  • Left Brain Rigging: An A-Z on Math and how it applies to rigging - two days (L29)
  • Left Brain Rigging Calculator - build your own spreadsheets for critical repetitive calculations (L30)
  • Tomcat USA: Safely Building the Beast - truss system design, fall arrest systems, ground supported systems - two days (L31)
  • Keep your Stage Rigging Happy & Healthy AR01)
  • Math for Riggers (Made Simple) (AR02)
  • System Integration Trends in Automation (AR03)
  • Is your GO Button Putting You at Risk? - Motor Control Technology & Risk Mitigation (ES01)
  • SIL Explained: Understanding European and Control System Safety Standards (ES02)
  • Fire Safety Curtain Systems - Closing the Door on Smoke (ES09)
  • Hook Up and Go! - Is Climbing on a Portable Structure Really That Easy? (ES10)
  • All About the ETCP (FS01)
  • ETCP paper & Pencil Exams at LDI - actually take the test(s)!
And of course, there will be lots of blinky lights and glittery things both inside and outside the convention center. Be There. See a Show. Have Fun. Learn Something.

More info at: www.ldishow.com/

Thursday, July 8, 2010

NFPA 80: Standard for Fire Doors and Protective Openings


Does this apply to your theatre?  If you have Fire Doors and/or Fire Curtains, then it most definitely applies if your locality has adopted this Fire Code.  This standard describes all of the requirements for testing and maintaining these critical fire and smoke containment elements.

How many times have you found stage doors physically propped-open with stage weights, chairs, desks, road cases, speakers, flag poles, kick-down door stops, rolled-up carpets, duct/gaffers tape, rope, or some other object?  This is clearly defined as a violation of the Fire Code and you should be able to instruct your staff as to why this is illegal and dangerous.

Do you know that Fire Doors and Fire Curtains must be inspected annually?  When was the last time yours were inspected?  What are you looking for when you do the inspection?  Which doors count as Fire Doors?  Overhead, hinged, sliding?  How fast (or slow) must the Fire Curtain close?  How often do they need to be tested?  What markings and signage are required?

Although the standard does not cover all of the aspects of Fire Doors and Fire Curtains - it does place most of the pertinent information in one location.  Like many things that the NFPA regulations cover, sometimes the answers are scattered across several different standards:
  • The routes that lead to the Fire Exits are discussed in NFPA 101: Life Safety Code.
  • The EXIT signs are addressed in NFPA 70: National Electric Code.
  • The Smoke Vents over the stage that work in conjunction with the Fire Curtain and Fire Doors are addressed in NFPA 204: Standards for Smoke and Heat Venting
  • The Fire Detection and Alarm System that may release electrically held Fire Doors, Fire Curtains, Smoke Vents, and Duct Shutters is addressed in NFPA 72: National Fire Alarm and Signaling Code
  • The smoke suppression system in the air ducts are defined under NFPA 90A: Standard for the Installation of Air-Conditioning and Ventilating Systems
Other related Codes:
  • Portable Fire Extinguishers are regulated by NFPA 10: Standard for Portable Fire Extinguishers
  • The Fire Sprinkler System is defined by NFPA 13
  • The Standpipe and Fire Hose requirements are in NFPA 14
The NFPA (http://www.nfpa.org/) publishes the standards and the books that discuss them, and they also present webinars to further educate people that have to understand and know how these items work. They have an upcoming webinar regarding NFPA 80 that you can sign-up for here:

You can subscribe to e-mail notices from the NFPA at:
http://www.nfpa.org/Catalog/RequestPrintCatalog.asp?src=catalog

Thursday, April 1, 2010

Getting NOT Kinky - Fire Curtain Release Perimeter Line

If you have a Fire Curtain in your theatre, then part of that protective system is a fire control line that surrounds the Fire Curtain perimenter on three sides (stage left, top, & stage right) and has fusible links that will separate should there be a fire in the immediate vicinity of the Fire Curtain.  That line must be a small diameter (3/8" fiber rope or 3/32" diameter 7x19 wire rope) cable so that it bends easily and move freely through the pulley blocks at the corners of the Fire Curtain.  Ref: 2010 NFPA 80, Section 20.7.3.2.

The bend radius of the cable is known as the D:d ratio.  This represents the ratio of the pulley sheave diameter (D) to the cable diameter (d).  The for 7x19 stranded wire rope the recommended D:d ratio is 51:1, so the recommended sheave diameter for 3/32" diameter cable is 51 x 3/32, which equals 153/32, or about 5".  The minimum ratio is 34:1, which is means that a 4" pulley is typically used as they are commonly available.  Ref: American Iron and Steel Institute "Wire Rope Users Manual, 2nd Edition", Table 9.


In the picture above we have a variety of design issues:

  • The cable is 1/8" diameter plastic-coated wire rope.  It is a bit larger diameter than the required 3/32", so it would require an even larger sheave, about 6".  As you can see, the pulley is only about 1-1.5" diameter, or about 1/4th the required size.  This can cause the cable to 'take a set' and get a kink in it so that it doesn't want to move freely through the sheave.  I've seen wire rope as large as 1/4" diameter used with pulleys like this - and they definitely take a set after resting immobile for years on end.

  • The cable's plastic jacket might melt and gum-up the works should there be a fire - not good.

  •  Although this rigging point isn't bearing a significant load, it's still jsut bad juju to use pot-metal dime-store clothes-line pulleys, twisted-link 'dog chain', and quick-links to string stuff up.  Man-up and install it right with load-rated equipment - after-all, this is a Fire Curtain System, not just a trick-line for a one-act play!
Test your Fire Curtain System every 90 days. Ref: 2010 NFPA 80, Section 20.7.1.3.
Have your Fire Curtain System Inspected Annually.  Ref: 2010 NFPA 80, Section 20.9.1.

Wednesday, March 31, 2010

Reading Material for the Masses

Over the years I've written a few articles and blurbs that people find interesting, and they were something that I've had to e-mail folks as they request them.  Not any more.  I've posted them online at two sites where you can download them for free as Adobe PDF documents.  Cool.  More free stuff.  You can fetch them at:

www.scribd.com/efriend2335



www.docstoc.com/profile/teqniqal

Saturday, March 27, 2010

The Stage Manager's Ready List

I recently attended a theatre festival that had many great portfolio and model set presentations by Directors, Stage Manager's, Sound Designers, Lighting Designers, Set Builders, and many other talented individuals.  It's great to see such a high level of creativity by those coming into the business!

Of particular interest were the presentations by the Stage Managers.  Each had presentations of check-lists, pre-show make-ready items, post-show to-do lists, and every other kind of list imaginable, except one: Emergency Procedures.  So the next time you're "making a list and checking it twice," take a moment and think about what you might / should do in the cases of:
  • Extreme weather conditions (flood, tornado, hurricane)
  • Injuries (both to crew and performers -- and to audience members)
  • Security (campus lock-down or evacuation)
  • Building Emergency (fires, earthquakes, broken water pipes, roof collapse, power outage)
  • Equipment failure (fire curtain comes-in accidentally, or maybe won't go-out, tripped sprinkler head - do you know where the shut-off valve is located?)

If you don't have a plan, then it is quite typical that you may end-up with total chaos on your hands.  How you handle an emergency can greatly influence the likelihood of injuries being sustained by the building occupants as they try to deal with the situation.

Have a plan (actually, several plans).  Post them.  Practice them.

Good places to hang-out:
Control Booth:  www.controlbooth.com
Stage Manager's Association www.stagemanagers.org
Production Manager's Forum www.foghouse.com/PMForum/index.html

Tuesday, October 6, 2009

Natonal Fire Prevention Week - A look back at the Iroquois Theatre Fire

Much hasn't changed in the last 100 years - I still routinely find Fire Exits blocked, dysfunctional Fire Curtains, and flammable scenery, props, and costumes in every theatre I visit.  These were the very cause of the Iroquois Theatre fire. Think about it!
Asbestos Fire Curtain in an older theatre

For a bit of perspective, visit the following web sites a read-up on this disaster
Please, think twice before you set the stage for another disaster.

Monday, October 5, 2009

National Fire Prevention Week: October 5-9, 2009


In honor of National Fire Prevention Week I thought it would be good to take a look back at one of the worst Theatre Fires that ever struck this industry. The Iroquois Theatre Fire in Chicago was integral in forcing the development of improved Fire Safety Codes and Building Codes. Although the facility was largely constructed from fire retardant materials, the fire started with scenery that was not fire-proof, the fire and smoke containment system failed, and many of the emergency egress routes were blocked.  In just a few moments, hundreds of people were killed.  A true tragedy in every sense of the word.

For those that are inclined to learn from the past, and sadly, realize that many theatres today suffer from EXACTLY THE SAME CONDITIONS, please read through some of the material at the following links:




Does your Fire Curtain work properly?  Does it meet all the current codes?  When was it last inspected?  When was it last tested?  Where are your records?  Where are your spare parts?  Where is the wiring diagram for the motorized hoist (if it has one)?  If you don't know the answer to any of these questions, find out!

If you need help getting this system properly designed and operating, please contact me.  Assessment of these critical Life Safety Systems is important to your staff, patrons, and performers alike.