Tuesday, September 15, 2015

Fire Door Safety Week - Jim Morrison would be proud

Lori Greene, blogger at IDigHardware! is a great resource for all things relating to fire doors, and her most recent post at LinkedIn is no exception.  Check it out: https://www.linkedin.com/pulse/fire-door-safety-week-lori-greene-ahc-cdc-ccpr-fdai (or if you are not a LinkedIn member, go to: http://idighardware.com/2015/09/fire-door-safety-week/).  Some of Lorrie's past posts can also be found at The Building Code Forum http://www.thebuildingcodeforum.com/forum/blogs/u74/
 Get them Inspected, Detected, and if necessary, Rejected

Tuesday, August 13, 2013

Risk Management for Rigging from ProSoundWeb

Andrew Martin, the originator of ATM Flyware, wrote a good guide for managing your show rigging assets in the March 28, 2013 edition of ProSoundWeb.  The article provides a short overview of Risk Management Guidelines and provides a series of example graphics to show you specific points of concern to watch-out for.
Example of SpanSet / Round Sling Inspection Points
The article can be found here:  www.prosoundweb.com/article/hanging_out_risk_management_for_rigging

Wednesday, April 24, 2013

Arbor Day - The Last Friday Before May!

Annual  -- To do something EVERY year.  Rigging Inspections should come to mind, and although 'Arbor Day' is intended to be the day we all plant a tree, or three, it should also be a reminder that the counterweight carriages (aka: 'Arbors') in our stage rigging need love, too.

We want to look over your equipment and make sure that everything is in proper order.
  • Nuts are tight.  The top and bottom rod nuts should both be checked to ensure that they are properly clamping the top and bottom arbor frames.
  • The rods and back-bone are straight.
  • Each cable and rope is properly secured.
  • The guide shoes are clean and properly fitted to the guide rails.
  • Spreader plates are spaced-along the length of the weight stack and not buried at the bottom.
  • Weight locks are present, and have screws in them to allow them to be tightened-down so they can hold the counterweights from jumping out of the arbor frame in the event of a run-away and crash.
  • Take the time to enumerate the arbors so they are easily identifiable regardless of what level they are positioned.
  • Check to see if anyone has maybe added extraneous weights to the system . . .
  • There are many more things to check as a part of the rigging system, so this wasn't a complete list.

    Remember: People are the most dangerous things in the theatre, so make sure that each person using the rigging system understands how to handle the weights, are secure so they can't fall over the weight loading railing, and they fully understand about using spreader plates, rope locks, and weight locking collars.  Using the tools you have properly can save lives!

    KEEP THOSE ARBORS BALANCED (also referred to as: "In weight").  Train your crews to pace their work so that the fly crew (loading bridge crew) can keep-up with the ground crew that may be loading or striping a batten.  Out of balance systems can lead to run-aways, and that can really rack-up a system:

    Friday, August 31, 2012

    PLASA releases Orchestra Lift Standard for Public Review

    BSR E1.42 – 201x, Entertainment Technology — Safety Standard for Orchestra Pit Lifts, is available for public review on the PLASA website until October 23, 2012.  The last day to comment is October 22, 2012.  It may be downloaded for free at http://tsp.plasa.org/tsp/documents/public_review_docs.php.

    Saenger Theater - New Orleans
    Saenger Theatre, New Orleans, with split lift for Orchestra and Organ Console

    BSR E1.42 is being written to address the lack of a national standard in North America for orchestra pit and forestage lifts, and to help establish minimum safety requirements and inspection procedures. The scope is limited to safety and to orchestra or forestage lifts that are installed as a part of the building and that are not custom-built for a single theatrical production.

    For more information, please contact Karl Ruling, PLASA's Technical Standards Manager, at karl (dot) ruling (at) plasa (dot) org

    Friday, July 13, 2012

    Keeping it all together

    GRC (Not the Nutrition Guys) is a term commonly used to abbreviate Governance, Risk Management, and Compliance in the safety industry.  It is supposed to be an organizational cohesion that coordinates the efforts of everyone in a business so that guidance (Governance) is uniformly applied to all the sub-groups, and the subgroups share information and resources openly.

    School Districts and Universities typically show significant separations between Risk Management (aka insurance claims management), Facility Safety (building and equipment maintenance), Public Safety (security), and personnel safety (actually training staff and students).

    Interdepartmental separations occur, too.  Why is it the automotive shop student is given protective eye wear, while the theatre shop student has to provide his own?  The disparities are numerous and sometimes frustrating.  It affects the supply of safety information, safety goods, safety training, and maintenance.  When properly implemented, it answers the question of "Who's going to pay for this?"

    For the governing administrators to do their jobs effectively, it is critical that they understand the wide variety of environments under their care.  In the theatre, this means that we have to pull-back the curtain and expose ourselves to the scrutiny of other non-theatre people.  This is hard.  We spend our entire careers trying to create magic and not let anyone outside of the theatre process know how it really works.  This is the exception.  When it comes to safety - everyone has to know and understand.

    Don't stand there and tell everybody that your theatre is safe.  It's not.  This blogger sees brand new theatres that are constructed unsafely all of the time, and few new facilities come with any significant amount of operational safety training - everybody just brings their old bad habits with them and go on with little or no thought as to how they might make cultural changes to their work process.

    In the 70's, the phone company ran a series of advertisements that said: "To communicate is the beginning of understanding."  The theatre plant is a perfect example of how important this is.  Maintenance workers need to access equipment and understand what is 'special' theatre equipment and know when they can work on it, and what is 'off limits' so that only specially qualified personnel are brought in to service it.  Good examples might be:
    • Dimmer Racks:  The air filters need to be cleaned regularly.  This may require that the power to the dimmer rack be disconnected because there may be live electrical parts within.  Chasing-off the cleaning crew and then not having the filters serviced may cause the dimmers to overheat and malfunction, or even catch fire.  At a minimum, it will shorten the life of the equipment.  This applies to the air filters for the workspaces around the theatre, too.  I've seen clogged air filters and air grilles in follow spotlight rooms, on stages, in dimmer rooms, and on dimmer racks - all preventable if the theatre staff would engage with the maintenance staff.
    • Stage Rigging:  Equipment must be inspected regularly by qualified personnel.  Most janitors and building maintenance crews are NOT trained or experienced enough to perform this task.  The maintenance of the stage rigging falls into this category.  The oil field rigging, construction rigging, or ship rigging backgrounds that some maintenance workers might have may be of some use, but without a knowledge of theatrical systems and how they are used, the resulting 'fixes' may be dangerous, incompatible with the theatrical operational needs, or aesthetically undesirable.
    • Fire Curtain, Smoke Vent, and Fire Doors:  Inspections and maintenance present challenges similar to the Stage Rigging.  Corrections that are not compatible with Fire Codes, Theatre Operations, and the Audience's enjoyment of the presentations must be prevented through the use of knowledgeable people.  Hire a consultant of you need one - this is where your Risk Management Department and or your Safety Office may be able to assist in securing the necessary funding.
    Finding a balance with safety equipment provision policies, cost deferrals, and training budgets can only be achieved if the various participants can speak openly about the needs of their buildings and operations.  It also requires that the administrators truly understand and acknowledge just how dangerous a theatre plant is.  They care about bad brakes on buses, broken playground equipment, football helmets, and toxic fumes in the chemistry lab - why should your performing arts venue be any different?

    Blogger Norman Marks on the Sustainable Business Forum site has a series of articles that help to explain GRC:  http://sustainablebusinessforum.com/node/59561

    Friday, March 30, 2012

    Show me a little tail, please

    The crimp oval on the left is done with a bit of the cable exposed above the metal, as it should be.

    On the right, we have one that came-up a bit short.  To get full strength out of the crimp it must be compressed down around ALL of the cables.

    Copper crimp ovals are preferred over aluminum ovals due to reports of cracks and splits in the softer aluminum.  Check your cable terminations regularly to see that they holding-up and were done correctly.
    Common tool manufacturers for compression fittings are:
    Also notice the split link used to connect the chain back to itself.  This device is not rated for overhead lifting and, therefore, should not be used for stage rigging.

    Tuesday, February 21, 2012

    Yeah, they have an app for that, too.

    The iAuditor application for the iPad provides a convenient way to deploy checklists to all of your department heads and workers.  This customizable tool allows you to set-up check-lists, take photos, sign the document, and e-mail it so you have a clear record of inspections.

    This app replaces paper-based reporting and allows the user to enhance reports with photographs showing compliance issues.  It also greatly reduces the likelihood of late submissions and falsified time-stamping.

    With a smart interface to build forms, iAuditor allows for forms to be created on-the-fly from within the app, a form can be created and modified to suit departmental needs throughout the theatre plant.  By giving users the power to create their own audits, iAuditor can be applied to thousands of situations. This level of customization in auditing has never been seen before in the safety industry.


    The iAuditor app has full GPS integration, too, so it can identify reports applicable to specific venues for large areas like theme parks, or be used on tour venue-to-venue.




    An unlimited number of forms and checklists can be created using the form building screen, and templates can be shared between users. Ready-to-use audit forms are also available for free download from the SafetyCulture Secure Online Cloud.

    Upon completion of an audit or checklist, the form can be quickly e-mailed as a PDF, which is compatible with almost any computer, smartphone, or tablet with a PDF reader application.

    An audit checklist can be used by workers to ensure they are meeting their reporting and record-keeping requirements. Uses include:
    • Life Safety Code Inspections
    • Occupational Heath and Safety Codes
    • Governmental Reporting Requirements
    • Fire Prevention Checklists
    • Building Safety Checklists
    • Electrical Safety Checklists
    • Ladder Safety Checklists
    • Pre-Show, Intermission, and Post-Show Checklists for both FOH and Backstage
    • Shop, Storage, and Loading Dock Safety Audits
    • Vehicle Inspections
    • Emergency Lighting & Exit Sign Inspections
    • Fire Extinguisher Inspections
    • Fire Door Inspections
    “Businesses all over the world are using technology to work smarter, not harder. We’ve listened to the people who are out in the field every day, and we’re committed to helping them work safer by using technology. With iAuditor, we’ve shown another example of this commitment; an incredibly versatile auditing and checklist app that is free to use and free to download.” Said Luke Anear, Managing Director of SafetyCulture Australia (www.safetyculture.com.au).

    More information about the iAuditor app can be found at: www.safetyculture.com.au/iauditor/

    Friday, August 19, 2011

    NFPA Announces New Editions of Codes and Standards

    Theatres are complex buildings, and they don't usually don't come with an Instruction Manual. You need to know what you can do, and what you can't do. And it usually helps if you can quote the authorities 'Chapter and Verse'.  This way people understand that it's not you that's being a pain in the butt, but that there really is a law, rule, or standard that defines the proper way to handle situations around the venue.

    The 2012 NFPA 101 Life Safety Code has been made available for purchase on the NFPA web site:
    http://www.nfpa.org/catalog/product.asp?pid=10112&title=2012-NFPA-101-Life-Safety-Code&category_name=&target_pid=10112&source_pid=10109&link_type=edition_change

    This edition has changes that relate to egress paths, so they have used that theme on the cover design.


    The 2012 NFPA 204 Standard for Smoke an Heat Venting (that smoke hatches / vents over the stage for the theatre folks) has also been updated and information can be found here:
    http://www.nfpa.org/catalog/product.asp?pid=20412&title=2012-NFPA-204-Smoke-and-Heat-Venting&category_name=&target_pid=20412&source_pid=20412&link_type=edition_change

    This describes the means of operations, quantity required, and recommended inspection procedures and scheduling.

    If you have a Fire Curtain (many theatres) or Fire Doors (almost all buildings), then you need to fully understand the requirements for inspecting and testing these critical devices.  The 2010 NFPA 80 Standard for Fire Doors and Other Opening Protectives is the key to this part of your facility management.

    This talks about door props, latches, crash bars, automatic closers, painting doors, and identifying Fire Doors.

    Also of interest to many is the 2011 NFPA 70 National Electric Code which is everything you need to know, and them some, about electrical issues.  There are sections about the wire and cable we are permitted to use in the theatre environment, special requirements for dressing room lights and power receptacles, and many important items.  Product information can be found here:
    http://www.nfpa.org/catalog/product.asp?pid=7011SB&title=Code-70-2011-National-Electrical-Code-NEC-Softbound&category_name=&target_pid=7011SB&source_pid=7008SB&link_type=edition_change

    The companion book for those working on electrical equipment (almost all of us, whether we should or not) is the 2012 NFPA 70E Standard for Electrical Safety in the Workplace.  This addresses Lock-Out-Tag-Out (LOTO) procedures, ArcFlash, working 'HOT', and many other life-threatening activities when working with electricity.
    http://www.nfpa.org/catalog/product.asp?pid=70E12&title=2012-NFPA-70E-Standard-for-Electrical-Safety-in-the-Workplace&category_name=&target_pid=70E12&source_pid=70E09&link_type=edition_change

    Many of the NFPA publications have companion Handbooks that are available that break-down the codes and standards into manageable concepts with great graphics and explanations describing both proper and improper conditions.

    Put these books in your budget.  Each one usually has a 3 to 5 year update cycle, so setting aside the funding for each of these should be a simple task.  If you need justification for the expenditures, then ask the powers that be how you are supposed to do your job without the actual books that define the Laws you must obey and the Standards to which you should adhere.

    Warning:  Reading these books may induce drowsiness. Do not drive or operate heavy machinery while reading them.

    Wednesday, April 27, 2011

    Arbor Day is Time to Check Your Arbors

    Your Counterweight Arbors are stressed-out.  Make them feel better by giving them a thorough check-up.  Doctor's Orders.

    Things to check:

    Top Plate Connections:
    • Make sure that all the screws, nuts, and bolts, are tight.
    • Check the Hauling Line rope to see that is secure and not worn.
    • Check the Lift Line Terminations to see that they are all secure.
    Not Good Example . . .

     Check to see that Spreader Plates are accessible and Weight Locking Rings are in-use.
    Not buried like this . . .
    Check to see that the rods nuts are tight:

    Tight nuts are good to keep your rod in place.
    And check to see of the lower rope connection is properly tied-off:
    Note the thimble to keep the rope from abrading on the lower arbor eye.

    Keep a good eye on your arbors and watch for loose parts!  If something gives-way it could be deadly!

    Every Day is Arbor Day in the Theatre


    Tuesday, September 7, 2010

    Rigging Report Card - Pass? -or- Fail!

    J.R. Clancy Company, one of the largest Stage Rigging component manufacturers in the world, has introduced a new posting section on their Facebook photos page.  It is a Bad Rigging Photo of the Week.  Log in and check it out.  Scary is an understatementwww.facebook.com/JRClancy

    These pictures, and similar ones I post here in the Theatre Safety Blog, and those that I show in my USITT workshops "What's Wrong With This Picture?" are all intended to make you take pause and think about what may be lurking in your theatre, or that theatre that you may be traveling to for your next show.

    These types of poorly thought-out assemblies really go to show you how important it is to have your facility inspected by an objective party.  Things that you may casually dismiss because you've come to see them every day may actually be a really serious hazard.  A fresh set of eyes can be key to getting a wake-up call.  Independent Consultants (insert shameless plug for my company, Teqniqal Systems, here) can be a great resource for this as they work objectively and are not interested in selling you new equipment, just seeing that you are aware of the current state of affairs with your facility.

    The NFPA 80 Standard for Fire Doors and Other Opening Protectives, 5.2, requires that you have your Fire Curtain inspected annually, so this is a good time to have the rest of the rigging system inspected as well.  If your facility is operating under OSHA (State plan, or Federal plan, or even if it's not - it's still a really good idea), then you are required to have your Rigging Systems inspected annually.

    Not to be forgotten, your Smoke Vents (an important part of the Fire Curtain System along with the Fire Doors) must be tested annually.  Your Smoke Vents should have rigging that facilitates the operation from the stage floor level (don't tell me you are going to go to the grid iron deck to open them to clear-out extraneous atmospheric effects or summer heat).  This smoke hatch rigging (be it mechanical or motorized) must be inspected semi-annually as a part of the Smoke Vent inspections.  Ref: NFPA 204 Standard for Smoke and Heat Venting, 12.4.3.5.

    Ask a lot of questions about the report that you are going to pay for.  What does the inspection include / exclude?  How long will it take?  Who should be present?

    "Will you shut me down if I fail?" is a common question I get.  My answer is this:  I'm just the messenger.  I report what I see and put it in context so you and your administration can understand it and the potential consequences.  I quote relevant building or safety codes, if applicable to the situation.  I am not the AHJ (Authority Having Jurisdiction).  You are my customer, so I report to you.  Your building condition is your business, so you can act on the report as you deem appropriate.  Hopefully, you will get the broken stuff fixed.

    One thing at a time:  Typically, a Rigging System Safety Assessment report will NOT include any design or specific engineered solutions.  It is only a report on the conditions.  Why is this excluded?  At the time I contract with you to perform the inspection, I will usually only know the general nature of the building layout and rigging systems, I will not yet have seen any of the actual conditions - how could I possibly estimate the cost of my services to (re)design a fix for what I have not seen?

    "How much does this cost?" is the battle cry of the administrators.  Don't be smug and ask them why it matters - or retort "Would they rather pay for a funeral?"  That's not the question.  "How much does it cost?" means that they need to find the funds and understand the value.  When they understand what this inspection entails, why it is important and/or necessary, then they can address the funding issue. You can help the process by remaining calm and professional.  Drama Queens can alienate the administrators if they present more bluster than facts.  A good consultant can help you to educate them about this investment / recurring annual maintenance cost.

    A little help on your part can be useful, too.  Do some research with your insurance provider, safety department, or even your regional / national arts groups.  Sometimes they have grant money available to help defray the cost of this work.  If it involves facility planning (that is what this is - planning for necessary improvements) and/or safety, the money is usually out there.

    The answer, like so many things in life, is: "It depends."  You should be suspicious of anyone that offers you a "Free" or "Discounted" rigging assessment.  It will likely be worthless and largely incomplete.  This type of work takes time.  Time = Money.  No one makes a living on 'free'.  At a minimum, you are paying for the person's travel time and expenses to and from your facility, the time on-site actually testing, inspecting, observing, interviewing, photographing, and documenting what they find.  They then must organize all their findings into a coherent report that addresses your specific facility and put the information in context.  Each item should be clearly tagged with recommendations as to what needs removed, repaired, replaced, re-designed, etc.  The time expended writing the report can be many times the hours spent on-site.

    The "It depends" factor is complex:  Do you have a walk-on gridiron?  Or do I need to rent a man-lift to go up a bazillion feet?  Do you have 1, 2, or 3 loading galleries?  How many line sets do you have?  How many are motorized?  Is this a Union House?  Am I inspecting just the Rigging System, or am I doing the Drapes,  Fire Curtain, Smoke Vents, and all the scabbed-on rigging at the Tormentors, Beam Electrics, Speaker Clusters, and Orchestra Shell components?  Is there an Orchestra Pit Lift?  Am I inspecting Fire Doors, Fire Alarms, and/or any other Life Safety Systems?

    Be efficient with your investment.  Is your facility part of a School or College District that has multiple venues?  If so, then seriously consider having all the venues inspected under one contract.  No, this isn't a money grab.  It is about identifying the sources of problems.  If your inspector can assess 2, 4, or a dozen facilities as a whole, then the report you receive should be more manageable.  The areas of common concern can be discussed once, and the unique 'features' of each system or building can be addressed individually.  This allows you and your administration to see items that are systemic in nature and those that are local in nature.  A big picture that speaks to all of the district's Theatre Safety needs can be a powerful impetus for change and improvements.

    Once the report is written and submitted, you will have a chance to read it and discuss it with your staff.  Don't shoot the messenger.  Understand that the inspector does not have an agenda, they are not 'out to get you', they are not seeking to close-down your theatre.

    As Sergeant Joe Friday would say: "Just the facts, ma'am."  Don't interpret the safety report as an indictment of your operations or management.  It is not.  However, it may point to some areas of your operations that could use improvement.  The most dangerous part of a rigging system is the people that operate it.  Use your rigging safety report to improve your policies, methodologies, and show preparation.  Use it to plan repairs, upgrades, and service.  Learn from it.

    Questions?  Call me or write me!

    Tuesday, July 20, 2010

    Honesty is always the best safety policy: CM Steps-up to the Challenge

    Well known electric chain hoist manufacturer Columbus-McKinnon (Commonly known as 'CM') issued a statement reminding customers about a known safety issue with some of their hoists.  This Safety statement pertains to questions about brake retaining pins on the company's hoists.

    The company statement follows:

    "There has been some information circulating recently within the Entertainment Industry in reference to brake retaining pins on Columbus McKinnon Hoists. This issue goes back to 2006 when Columbus McKinnon issued the attached notice concerning a small number of brake retaining pins for the following hoists: Prostar, Shopair, Shopstar, Shophoist, Model CPS, Budgit Series, Coffing SLC, Little Mule SLM and Yale SAL powered chain hoists built between February 2005 and April 2006. The serial numbers that were affected had the last two letters of RP, RQ, RR, RS, RT, RU, RV, RW, RX, RY, RZ, SA, SB, SC and SD.


    "Columbus McKinnon did notify at that time every distributor that purchased the affected hoists and sent out replacement pins. Our distributors did a good job of notifying their customers and having the pins replaced. However it has come to our attention that some end users of the affected hoists may not have replaced the brake pins. If you have a hoist model and serial number listed above and the brake pin has not been replaced, please contact Columbus McKinnon directly at the number below.


    Dean Sullins or Lee Gregor
    1-800-634-4647
    dean.sullins@cmworks.com
    lee.gregor@cmworks.com"

    Support manufacturer's that support your safety (and the gear above your heads).  CM LoadStar Hoist School is a great way to get first-person training (www.cmcodepot.com/cm-ettraining.aspx) regarding the hoists used by many of the touring show professionals around the world.

    Visit CM's Entertainment Industry hoist web site (www.cm-et.com/) for more information.  These are versions of their commercial hoists that are specifically tailored to the unique needs of the show production industry.

    Saturday, April 3, 2010

    Doors - Not just for Jim Morrison

    Did you know that Fire Doors must be inspected annually? Yup, just like a Fire Curtain. Ref: 2010 NFPA 80, chapter 5.2.1. Most doors in an institutional building are Fire Doors, and an easy way to verify if a door is a Fire Door it is to look at the edge of the door leaf that is attached to the hinges.


    If it is a Fire Door then you will see a small metal placard that says: FIRE DOOR and a bunch of other information about the door.  Look closely if you don't see it at first -- it may have been painted-over -- which is also a fire code violation. Ref: 2010 NFPA 80, chapter 4.2.2.

    Inspections of Fire Doors are to check that the door is:
    • There (yes, I find them missing sometimes).
    • In proper operating condition (windows not broken, operating hardware all functioning).
    • The latches work (and aren't covered with gaffer's tape) - this is so the door can stay closed against the atmospheric forces of a fire.
    • The crash-bar (panic hardware) works and allows the door to open (no extra dead-bolts, pad-locks, or chains).
    • To make sure the door is not blocked on either side in a manner that would prevent it from being opened (things like pianos, stacks of chairs or desks, book cases, filing cabinets, cars, trucks, orchestra shells, etc.).
    • To make sure that the door is not propped open in a manner that would prevent it from being closed automatically (this means NO stage weights, NO chairs, NO desks, NO microphone stands, NO speakers, NO road cases, NO scenery, NO flag pole bases, NO . . . well, you should get the point).
    • To see if the automatic door closer hardware actually automatically closes the door (this is how you keep the smoke-in, air out, and keep the fire from spreading).  Disconnected, clamped, maladjusted, or broken closers must be repaired or replaced.
    • To  make sure that 'extra things' haven't been added to the door like kick-down door props (no, you cannot add these to Fire Doors!) or bailing wire to tie the door open.
    • And to check that the magnetic door release latch, if any, is properly working in conjunction with the Fire Alarm System (yes, this is the only legal way to prop a door open).

    Thursday, April 1, 2010

    Getting NOT Kinky - Fire Curtain Release Perimeter Line

    If you have a Fire Curtain in your theatre, then part of that protective system is a fire control line that surrounds the Fire Curtain perimenter on three sides (stage left, top, & stage right) and has fusible links that will separate should there be a fire in the immediate vicinity of the Fire Curtain.  That line must be a small diameter (3/8" fiber rope or 3/32" diameter 7x19 wire rope) cable so that it bends easily and move freely through the pulley blocks at the corners of the Fire Curtain.  Ref: 2010 NFPA 80, Section 20.7.3.2.

    The bend radius of the cable is known as the D:d ratio.  This represents the ratio of the pulley sheave diameter (D) to the cable diameter (d).  The for 7x19 stranded wire rope the recommended D:d ratio is 51:1, so the recommended sheave diameter for 3/32" diameter cable is 51 x 3/32, which equals 153/32, or about 5".  The minimum ratio is 34:1, which is means that a 4" pulley is typically used as they are commonly available.  Ref: American Iron and Steel Institute "Wire Rope Users Manual, 2nd Edition", Table 9.


    In the picture above we have a variety of design issues:

    • The cable is 1/8" diameter plastic-coated wire rope.  It is a bit larger diameter than the required 3/32", so it would require an even larger sheave, about 6".  As you can see, the pulley is only about 1-1.5" diameter, or about 1/4th the required size.  This can cause the cable to 'take a set' and get a kink in it so that it doesn't want to move freely through the sheave.  I've seen wire rope as large as 1/4" diameter used with pulleys like this - and they definitely take a set after resting immobile for years on end.

    • The cable's plastic jacket might melt and gum-up the works should there be a fire - not good.

    •  Although this rigging point isn't bearing a significant load, it's still jsut bad juju to use pot-metal dime-store clothes-line pulleys, twisted-link 'dog chain', and quick-links to string stuff up.  Man-up and install it right with load-rated equipment - after-all, this is a Fire Curtain System, not just a trick-line for a one-act play!
    Test your Fire Curtain System every 90 days. Ref: 2010 NFPA 80, Section 20.7.1.3.
    Have your Fire Curtain System Inspected Annually.  Ref: 2010 NFPA 80, Section 20.9.1.

    Thursday, November 19, 2009

    Auditorium Safety Webinar Now Available at SchoolDude


    These folks have graciously invited me to co-present a webinar about auditorium safety management. The event was live on Nov 18, 2009 and titled "Facility Masters Webinar Series: Auditorium and Theatre Safety".  It has been archived and can be viewed at http://discover.schooldude.com/forms/2009-11-RY-FM-MD-AuditoriumSafety.

    At the SchoolDude web site you can watch and listen to the presentation by Host Roger Young, New Mexico Deputy Fire Marshal Ray Wolf, myself, and SchoolDude Mayor David Kornegay.  There are also many document and presentation downloads available.

    Depending upon your area of theatre involvement, some aspects of this webinar may not seem interesting, however, please be patient and take the time to watch and listen all the way through it. There are points of information throughout it that relate directly to the theatre safety issues.  Please pass this link on to your school maintenance and management officials, too, so that they can see how facility management relates to theatre safety.

    Monday, October 5, 2009

    National Fire Prevention Week: October 5-9, 2009


    In honor of National Fire Prevention Week I thought it would be good to take a look back at one of the worst Theatre Fires that ever struck this industry. The Iroquois Theatre Fire in Chicago was integral in forcing the development of improved Fire Safety Codes and Building Codes. Although the facility was largely constructed from fire retardant materials, the fire started with scenery that was not fire-proof, the fire and smoke containment system failed, and many of the emergency egress routes were blocked.  In just a few moments, hundreds of people were killed.  A true tragedy in every sense of the word.

    For those that are inclined to learn from the past, and sadly, realize that many theatres today suffer from EXACTLY THE SAME CONDITIONS, please read through some of the material at the following links:




    Does your Fire Curtain work properly?  Does it meet all the current codes?  When was it last inspected?  When was it last tested?  Where are your records?  Where are your spare parts?  Where is the wiring diagram for the motorized hoist (if it has one)?  If you don't know the answer to any of these questions, find out!

    If you need help getting this system properly designed and operating, please contact me.  Assessment of these critical Life Safety Systems is important to your staff, patrons, and performers alike.

    Thursday, September 24, 2009

    It's 10:00 - Do you know where your Fire Extinguishers are?


    When you have fire extinguishers in your facility it is very important that you and your staff:
    • Know where they are
    • Know when they were last inspected
    • Know how to use them

    Knowing where they are is important not just for you and your staff, but for the person that has to check them as well. I frequently find units in the same building that have five or six different inspections YEARS. It is obvious that each successive inspector did not know where all of the fire extinguishers were located. Suggestion: Draw a building floor plan and annotate the location of all of the fire protection devices:

    • Fire Extinguishers
    • Fire Alarm Pull Stations, Smoke Detectors, Rate-of-Rise Heat Detectors
    • Special Devices (Fire Door releases, Fire Curtain(s), Smoke Vent(s), Elevator Lobbies)
    • Fire Alarm Control Panel (FACP)
    • Alarm Strobes, Horns, Bells
    • Emergency Lights
    • Fire Sprinkler Heads
    • Fire Hose Cabinets

    Keep it filed with your inspection records, and post copies for your staff. Other good information to keep with this would include contacts:

    • Fire Marshal
    • Fire Alarm Company
    • Fire Sprinkler Company
    • Fire Extinguisher Service Company
    • Rigging System Service Company
    • Smoke Vent System Service Company

    Note the dates on the inspection tag in the picture above -- they are ambiguous (no year), and difficult to read. To help identify yearly inspections are being done on all equipment, use a different color of tag each year (red, yellow, blue, green, white, etc.) so that non-conforming tags stand-out more noticeably.

    Know when and how to use a fire supression device. Get training for your staff and students. If you can't actually put-out a real fire, then do the next best thing and use a fire extinguisher training device like the BullsEye or I.T.S. Extreme from BullEx Safety (http://www.bullexsafety.com/).

    Friday, June 26, 2009

    Lineset Numbering - It's not just for the index strip!

    Here are some good examples of rigging management. Not only are the index strips and arbors CLEARLY numbered, but the batten end, loft blocks, and head blocks are also marked.

    This also makes it easy to keep lineset inspection records straight during your annual safety check-up.

    Monday, June 8, 2009

    Those aren't all they're cracked-up to be.


    Modern rope locks are made from formed & welded steel plates. Older ones were made with cast metal and are more prone to stress cracks, and ultimately failure. Another good reason to do an annual inspection! Never load you rope locks to more than the recommended 50 pounds - keep your sets balanced and 'in-weight'. The rope lock may be stronger, but do you really want to find-out? This is also why you don't want to use your rope locks for rope brakes -- a dynamic load like a moving set and/or counterweight carraige can place much more strain on a rope lock than you would ever imagine.