Wednesday, April 14, 2010

The Big Red Word vs. the Little Green Man

SLATE author Julia Turner has a great article about the ongoing controversy between the common US  EXIT  sign and the internationally recognized ISO standard 'running man' sign.

You can read it here:  http://www.slate.com/id/2246107/

Friday, April 9, 2010

Get a grip - a really tight grip

Tools for crimping compression ovals onto wire rope cable can be, shall we say, a bit unwieldy at times.  Actually, almost always.  An if you are not built like a linebacker, they can flat wear you out if you have dozens - nay hundreds - of crimps to perform.  Enter a really workable solution from Nicopress:  The
Nicopress® Model 5606.  Much cooler than Luke Skywalker's Light Saber (but only because you can actually own one of these).



Features:
• One hand operation; lightweight & slim
• Visible orange weather resistant housing
• Audible bypass when predetermined pressure is achieved
• Crimping jaws can be opened mid-cycle to adjust connection
• Crimp cycle time:  Less than 6 seconds
• Battery charge time: Less than 1 hour, about 250 sleeves for 1/4" wire rope can be compressed per charge.
• Jaws rotate 360 degrees for ease of use in confined spaces.
• Weight: 6.75 lbs. with Lithium Ion Battery
• Dimensions: 20.5" L x 4" H x 2.5" W
• Wire Rope Die Sizes: 3/64" thru 5/16" diameter

The top button (thumb) initiates the crimp action, and the bottom button releases the jaws.

Interesting side note:  The crimp dies for 1/4" wire rope only require two compressions, unlike the hand tool's three, so when you are doing inspections, and find fewer crimps, it doesn't necessarily mean that it was done wrong, but instead it may have been done with a different tool / die than what you are accustomed to seeing.

Info at:  www.nicopress.com/products/toolh-wr-5606

Wednesday, April 7, 2010

You can Huff and Puff, but you won't blow down this Brickhouse

Say what you will about counterweight rigging being medieval, it still goes into a lot of stages and is used every day by many people.  So, if you're going to do it, you might as well make it safer.  At USITT 2010 in Kanasas City, Thern Stage Equipment Company introduced the "Brickhouse Front-Loading Counterweight Arbor System".  This takes a whole new approach at how you handle the counterwights as they are loaded and unloaded, and also takes a new look at securing them in the arbor carraige.

The first thing one notices it that the Brickhouse has side walls and three compartments for counterweights.  This allows you to load weights into the most convenient compartment to access, rather than reaching high or low and possibly overextending oneself.

The next convenience is that as you place weights in the Brickhouse, you don't need two hands to do it.  No awkward twisting, tilting, or finagling of the weights to get them in-between the arbor rods.  Why?  Well, there is no back rod, and the front rod conveniently swings out of the way so you can just slide the weight 'bricks' into the compartment, which is sloped a bit to help with the process.

The weights have a handle built right into them, too.  What a concept:  A counterweight that you can grab onto with one hand and hold it securely without fear of dropping it.  This leaves your other hand free to hang-on for dear life (you are wearing a fall prevention / arrest system as you load weights, right?)

Once the weights are nestled into their compartments (and you can fill the compartments all the way to the top, too), you just swing the front arbor rod back into place and let 'er fly.

Drop testing shows that a stage heavy line set will crash throught the lower arbor stop just like a regular arbor (no surprise there), however, the side walls are built to take a lickin'-and-keep-on-tickin', so you shouldn't have a mess of bricks jumping out of the Brickhouse.  No word yet on the potential for bricks jumping out of the Brickhouse in the event of a stage-heavy run-away, but given the design of the compartments, it looks like the weight-lock free design still keeps them under control and not raining-down a hail storm of steel plates on the fly crew should a line set get away from you.  That said, I'm still wearing my hard hat PPE when I'm onstage or in the fly galleries - there are still a lot of other hazards out there to ping your skull.

More info can be had at: http://www.thernstage.com/products/rigging-systems/counterweight-systems.html

Sunday, April 4, 2010

Yech! Get that stinky thang out of my grille!

It's 10:00 o'clock.  Do you know where your microphone has been?  Who's been playing tonsil hockey with it?  Or worse?  Didn't think so.  Most people don't bother to think about those things.  Too yucky.  I know it puts shivers down my spine when I do.

Fortunately, somebody does care.  The folks at Microphome have just what you and your band needs to keep from contracting the next deadly thing (well, at least it might make those stupid germs think twice about who they're foolin' with).  Professional Mic Cleaning Foam.  Don't leave home without.  They claim it kills 99.9% of germs on the stuff it touches.


Check-out the product at www.microphome.com -or- www.microphome.org (which in this case I'm thinkin' they mean organism).

It's just like spraying shaving cream on your favorite '58, but it's hittin' the gross stuff head-on.

For another blog entry on the subject, see:
http://theatresafetyblog.blogspot.com/2010/08/who-knows-where-that-thangs-been.html

If you still don't  believe this is a good idea, then go to:
http://theatresafetyblog.blogspot.com/2012/05/yech-picture-is-worth-thousand-words.html


What's on your mic?

Saturday, April 3, 2010

Doors - Not just for Jim Morrison

Did you know that Fire Doors must be inspected annually? Yup, just like a Fire Curtain. Ref: 2010 NFPA 80, chapter 5.2.1. Most doors in an institutional building are Fire Doors, and an easy way to verify if a door is a Fire Door it is to look at the edge of the door leaf that is attached to the hinges.


If it is a Fire Door then you will see a small metal placard that says: FIRE DOOR and a bunch of other information about the door.  Look closely if you don't see it at first -- it may have been painted-over -- which is also a fire code violation. Ref: 2010 NFPA 80, chapter 4.2.2.

Inspections of Fire Doors are to check that the door is:
  • There (yes, I find them missing sometimes).
  • In proper operating condition (windows not broken, operating hardware all functioning).
  • The latches work (and aren't covered with gaffer's tape) - this is so the door can stay closed against the atmospheric forces of a fire.
  • The crash-bar (panic hardware) works and allows the door to open (no extra dead-bolts, pad-locks, or chains).
  • To make sure the door is not blocked on either side in a manner that would prevent it from being opened (things like pianos, stacks of chairs or desks, book cases, filing cabinets, cars, trucks, orchestra shells, etc.).
  • To make sure that the door is not propped open in a manner that would prevent it from being closed automatically (this means NO stage weights, NO chairs, NO desks, NO microphone stands, NO speakers, NO road cases, NO scenery, NO flag pole bases, NO . . . well, you should get the point).
  • To see if the automatic door closer hardware actually automatically closes the door (this is how you keep the smoke-in, air out, and keep the fire from spreading).  Disconnected, clamped, maladjusted, or broken closers must be repaired or replaced.
  • To  make sure that 'extra things' haven't been added to the door like kick-down door props (no, you cannot add these to Fire Doors!) or bailing wire to tie the door open.
  • And to check that the magnetic door release latch, if any, is properly working in conjunction with the Fire Alarm System (yes, this is the only legal way to prop a door open).

Friday, April 2, 2010

Alright, Bugsy - It's curtains for you!

Didja ever notice how Directors hate it when the theatre is suddenly flooded by light when a door is opened?  Yeah, it happens all the time.  It's really not their fault, it was the person designing the building that failed to recognize how disruptive this can be.

Denial is not just a river in Egypt.  It sometimes stems from a complete lack of admission that anyone would enter or leave a performance at anytime other than the designated time (yeah, like that's gonna happen!).

So what we get instead is folks trying to make-do.  They string-up curtain rods and cover the Exits to block the stray light.  Sometimes they cover the  EXIT  signs, too.  News Flash:  You cannot block or obscure a Fire Exit Door or Fire Exit Route.  Ref: 2010 NFPA 80, chapter 5.2.13.

Thursday, April 1, 2010

Getting NOT Kinky - Fire Curtain Release Perimeter Line

If you have a Fire Curtain in your theatre, then part of that protective system is a fire control line that surrounds the Fire Curtain perimenter on three sides (stage left, top, & stage right) and has fusible links that will separate should there be a fire in the immediate vicinity of the Fire Curtain.  That line must be a small diameter (3/8" fiber rope or 3/32" diameter 7x19 wire rope) cable so that it bends easily and move freely through the pulley blocks at the corners of the Fire Curtain.  Ref: 2010 NFPA 80, Section 20.7.3.2.

The bend radius of the cable is known as the D:d ratio.  This represents the ratio of the pulley sheave diameter (D) to the cable diameter (d).  The for 7x19 stranded wire rope the recommended D:d ratio is 51:1, so the recommended sheave diameter for 3/32" diameter cable is 51 x 3/32, which equals 153/32, or about 5".  The minimum ratio is 34:1, which is means that a 4" pulley is typically used as they are commonly available.  Ref: American Iron and Steel Institute "Wire Rope Users Manual, 2nd Edition", Table 9.


In the picture above we have a variety of design issues:

  • The cable is 1/8" diameter plastic-coated wire rope.  It is a bit larger diameter than the required 3/32", so it would require an even larger sheave, about 6".  As you can see, the pulley is only about 1-1.5" diameter, or about 1/4th the required size.  This can cause the cable to 'take a set' and get a kink in it so that it doesn't want to move freely through the sheave.  I've seen wire rope as large as 1/4" diameter used with pulleys like this - and they definitely take a set after resting immobile for years on end.

  • The cable's plastic jacket might melt and gum-up the works should there be a fire - not good.

  •  Although this rigging point isn't bearing a significant load, it's still jsut bad juju to use pot-metal dime-store clothes-line pulleys, twisted-link 'dog chain', and quick-links to string stuff up.  Man-up and install it right with load-rated equipment - after-all, this is a Fire Curtain System, not just a trick-line for a one-act play!
Test your Fire Curtain System every 90 days. Ref: 2010 NFPA 80, Section 20.7.1.3.
Have your Fire Curtain System Inspected Annually.  Ref: 2010 NFPA 80, Section 20.9.1.