Friday, April 23, 2010

STOP! In the name of love (of keeping your body parts intact)

I don't know about you, but when it comes to power tools, they can be a bit scary when you realize that they can grab your cloths, hair, or the part you are working on and tear them-up in a fraction of a second.  Drill presses, router tables, planners, and table saws are some of the most powerful tools in your shop, so having a shut-off switch that is extremely visible and easy to slam a hand or knee onto is a really good idea.


Grizzly Power Tools (http://www.grizzly.com/) makes the H8243 mondo power switch for this application.  For the price of a good pizza this dual voltage, single-phase Paddle Switch is rated for 110 Volt, 2 HP motors up to 35 amps, and 220 Volt, 3 HP motors up to 20 amps. The large paddle makes this switch ideal for emergency shut-offs.  It fits a standard single-gang electrical box, so you can mount it just about anywhere.

ANSI Standard 535.1 requires that the RED switch be mounted on a yellow background for maximum visibility, so slap a coat of yellow down before you mount that switch.

Do I have to have this?

According to most international machinery safety standards you probably should.  Here is a listing of relevant requirements for E-stops:
  • 98/37/EC The Machinery Directive - Clause 1.2.4 in annex 4 gives requirements for the emergency stop function for new machines. See also clause 1.2.2 Control devices (chapter “Standard and Regulations”).

    Council Directive 89/655/EEC of November 30, 1989 concerning the minimum safety and health requirements for the use of work equipment by workers at work, Clause 2.4 gives the requirements for the emergency stop function for older machines. See also clause 2.1 (chapter “Standard and Regulations”).
  • EN ISO 13850 Safety of Machinery - Emergency stop—Principles for design.  A harmonized standard that gives technical specifications for the requirements on the Machinery Directive.  Can also be used for older machinery.
  • EN 60204-1 Safety of Machinery - Electrical equipment of machines —Part 1: General requirements.  This is a harmonized standard that gives requirements for the electrical equipment of machinery including the emergency stop actuator/function. See clauses 9.2.2 and 9.2.5.4.2.
  • OSHA publication "Safeguarding Equipment and Protecting Employees from Amputation" can be downloaded here: www.osha.gov/Publications/osha3170.pdf

For industrial safety switch systems that meet a much higher level of performance, you need to look toward systems that are engineered solutions that utilize specialized sensors, switches, relays, and annunciators.  While the Grizzly paddle switch is a huge step in the right direction, there is still much more you can do to safeguard your shop workers.

Also see:
www.theatresafetyblog.blogspot.com/2011/12/power-play.html 
and
www.theatresafetyblog.blogspot.com/2012/05/stopin-startin-power-control-for-your.html

Thursday, April 22, 2010

Oh! My Aching Back!

It is estimated that 80% of the population has experienced back pain or discomfort in their working lives.  In the theatre we move a lot of equipment around, many times while reaching out or leaning over railings.  Stacking boxes, loading trucks, lifting counterweights, moving chairs, and working with platforms and staging are but a few of the things we do that could strain your back.

When we lift a load, we use muscles in the low back as part of a lever system. Unfortunately, because the muscles in our low back are only about two inches from the spine, the further a load is from our body, the more stress transfers to the low back and the amount of work required increases. Think about snow on the branch of a tree; the further the snow is from the trunk, the more the branch bends under its weight.

The National Institute for Occupational Safety and Health (NIOSH) developed a model that determines whether a lifting task is safe. The result of the NIOSH Lifting Equation is the Recommended Weight Limit (RWL), a weight that 99% of males and 75% of females should be able to lift safely. Under perfect circumstances — lifting an object with good handles only once in a certain posture — the highest possible RWL is 51 pounds. In calculating the RWL, other factors are also considered including horizontal distance, vertical location at the beginning of the lift (floor level is the least desirable), and whether there is twisting during the lift.

The NIOSH Lifting Equation makes it is easy to identify opportunities for design improvements. By working with the numbers, you can quantify the risk reduction that results from raising a load from the floor (0") to table height (30"), or decreasing the width of a table to minimize reach distance. The equation is equally useful for identifying ergonomic solutions, as well as ergonomic challenges.

Use the right tool for the job!
When I was about 10 years old I was sitting at the kitchen table trying (without much success) to strip the insulation from a 26 gauge wire with a big old and well worn set of linesman’s Kleins (heavy duty wire cutters for 8 & 10 gauge solid conductor steel wire).  My father came by and saw my frustration, brought me a set of small gauge wire strippers, and lectured me: ”Don’t use a Blacksmith’s tools to do a Jeweler’s job!”  We have forklifts, pallet jacks, carts, winches, pulleys, block-and-tackle, j-bars, and most importantly — other people, to help us. We are not Iron Man, Superman, or the Incredible Hulk, so don’t be shy, get help!  It’s better to be called a ‘wimp’ than to be called at the hospital.

Caveat to the Equations:  The NIOSH Lifting Equation does not apply if any of the following occur:
  • Lifting/lowering with one hand
  • Lifting/lowering for over 8 hours
  • Lifting/lowering while seated or kneeling
  • Lifting/lowering in a restricted workspace
  • Lifting/lowering unstable objects
  • Lifting/lowering while carrying, pushing or pulling
  • Lifting/lowering with wheelbarrows or shovels
  • Lifting/lowering with high-speed motion (faster than 30 inches/second)
  • Lifting/lowering with unreasonable foot floor coupling (<0.4 coefficient of friction between the sole and the floor)
  • Lifting/lowering in an unfavorable environment (i.e., temperature significantly outside of 66-79 degree F range; relative humidity outside 35-50% range
So, that covers almost everyting we do in the theatre.  What good are all these equations?  What can we do?  Think before your lift!  When in doubt, get help.  Ergonomics aren't about egos or machismos - it's about planning your work task so it doesn't tear-up your body.  Work smarter, not harder.

Resources:
NIOSH:  http://www.cdc.gov/niosh/docs/94-110/
NIOSH:  http://www.cdc.gov/niosh/docs/2007-122/
NIOSH:  http://www.cdc.gov/niosh/docs/2007-131/
NIOSH Lifting Equation (on-line calculator): http://www.emcins.com/losscontrol/quick_links/employee_safety_health/ergonomicsNIOSH.aspx
UCLA Ergonomics Lab: http://www.ergonomics.ucla.edu/
Canadian OSH (with online metric calculator): http://www.ccohs.ca/oshanswers/ergonomics/niosh/

Wednesday, April 21, 2010

How fast can you figure-out your Fall Protection Clearance?

PeakWorks has released a new application for the iPhone that calculates the clearance required for your fall arrest system to function properly.


They seemed to resist the urge to call it iFall.  The free application calculates the safe distance required based upon the harness type, anchor point elevation, and other factors.  More information about the application can be found at:
http://itunes.apple.com/ca/app/peakworks-fall-clearance-calculator/id359065407?mt=8

Information about PeakWorks fall protection systems can be found at:
http://www.peakworks.ca/

Tuesday, April 20, 2010

Rung for your life!


Ever have to make one of those reeeally long ladder climbs?  Didja wonder if you were ever going to get to the top (or the bottom, for that matter)?  Your hands can get sweaty and your boots might have a bit 'o crud on them . . . you get a bit tired . . . next thing you know:  you lose your grip, or your foot misses the mark.  This may be an annoyance, or it could be a lot worse.

Fall protection systems for ladders are only required for ladders more than 15 feet tall (you can see the harness attachment rail at the center line of this one).  This may keep you from falling to the ground, but you may still bust your face on the ladder before you regain you composure (yet another good reason to have a chin strap on your hard-hat!).

Many of the ladders you may encounter are right at or just short of the 15 foot limit, so all you have to protect you is your good grip on the ladder.  You can install fall arrest devices on ladders less than 15', too, and it is a really good practice.

Safeguard Technologies has a solution:  Formed fiberglass overlays that are fabricated to fit a variety of ladder rung diameters from 3/4" to 2" diameter.  The covers have hi-traction grit embedded in the material to provide a slip-resistant texture to the surface.  These can be applied to scaffold climbing rails, too, which are notoriously slippery - why do the scaffolding manufacturers coat these with glossy powder-coat paint?!
A ladder rung cover being installed with adhesive.

Ladders rungs nicely visible and with very high traction.

Now for the cool part:  Since these are made-to-order to fit the rung width and rung diameter of your facility's ladders, they can fabricate the rung covers with photoluminescent pigment in the fiberglass binder.  This can help you find your way down from the catwalk or gridiron in the dark should the power go out.

Resource:  Safeguard Technology (http://www.safeguard-technology.com/)

Friday, April 16, 2010

So, just where is that Fire Extinguisher? I know I saw around here somewhere . . .

Oh, here it is - tucked away behind this fake ficus tree.  It's a good thing we have decorative things to cover-up those ugly fire fighting tools!  It sure would be terrible if the audience actually saw them.
Ref: OSHA: 1910.157 Fire Protection - Portable fire extinguishers.

"1910.157(c)(1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury."

Thursday, April 15, 2010

Yup, we've got all of our Fire Extinguishers safely locked away . . .

Instructions:
  1. Find Key to Fire Extinguiser cabinet padlock, go to step 5, -or-
  2. Find safety goggles and put them on.
  3. Find heavy object to bash out glass.
  4. Reach past broken glass edges and retreieve Fire Extinguisher.
  5. Find wire cutter.
  6. Cut tie wire on Safety Pin.
  7. Pull Pin.
  8. Aim at base of fire.
  9. Squeeze handle.
  10. Sweep back and forth across base of fire.
Do ya think maybe some one missed the training module about putting-out little fires BEFORE they become BIG FIRES?